| IS-1 Coupler | 5mm Coupler | 6mm Coupler | |
| Model | VKU-10V (10cm length) VKU-20V (20cm length) VKU-40V (40cm length) |
VKU-10M (10cm length) VKU-20M (20cm length) VKU-40M (40cm length) |
VKU-10C (10cm length) VKU-20C (20cm length) VKU-40C (40cm length) |
| Conductor | Quadrifilar Coil | Quadrifilar Coil | Quadrifilar Coil |
| Insulation material | Silicone | Silicone | Silicone |
| Connector | IS-1 | 5mm | 6mm |
| Length | 10, 20 or 40cm | 10, 20 or 40cm | 10, 20 or 40cm |
Extends an implanted
unipolar lead, which connector was removed, to an implantable pacemaker.
The VKU lead extension incorporates a choice of connectors (either IS-1,
5mm or 6mm) on one end and the universal coupler with self sealing plastic
screws on the other end. The exceptionally constructed coupler warrants
a secure mechanical and correspondingly an excellent electrical contact
between the conductor of the lead and the coupler.
The clear coupler material facilitates the visual inspection of the splice.
For additional
information,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model |
2xBIS/BIS-17
(17cm length) |
| Conductor | Quadrifilar Coil |
| Insulation material | Silicone |
| Connector | Bipolar IS-1 |
| Receptacle |
Two Bipolar IS-1 |
| Length | 17cm / 40cm |
The 2xBIS/BIS is a bipolar implantable lead Adaptor which enables the adaptation of two bipolar leads having IS-1 connectors to one bipolar IS-1 pacemaker header cavity. Standard lengths are 17cm and 40cm.
For additional
information,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model | BVS/VS-15 (15cm length) BVS/VS-20 (20cm lenght) |
BVS-15
(15cm length) |
| Conductor | Quadrifilar Coil | Quadrifilar Coil |
| Insulation material | Silicone | Silicone |
| Connector | Bipolar IS-1 | Bipolar IS-1 |
| Receptacle | Two
unipolar IS-1 |
Two unipolar 5mm |
| Length | 15cm / 20cm | 15cm / 20cm |
Implantable bifurcated lead Adaptor consisting of two unipolar IS-1 or two unipolar 5mm receptacles to one bipolar IS-1 connector. Standard lengths are 15cm and 20cm.
For additional
information,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model |
BIS/BIS-17
(17cm length) |
| Conductor | Quadrifilar Coil |
| Insulation material | Silicone |
| Connector | Bipolar IS-1 |
| Receptacle |
Bipolar IS-1 |
| Length | 17cm / 40cm |
The BIS/BIS is a bipolar implantable lead extension which enables the extension of one bipolar lead having IS-1 connectors to one bipolar IS-1 pacemaker header cavity. Standard lengths are 17cm and 40cm.
For additional
information,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
Copyright © 2002 Oscor Inc. All rights reserved.
| Model | C/VS-10 |
M/VS-10 |
VS/M-10 |
LV/IS-10 |
| Conductor | Quadrifilar Coil | Quadrifilar Coil | Quadrifilar Coil | Quadrifilar Coil |
| Insulation | Silicone | Silicone | Silicone | Silicone |
| Connector | Unipolar IS-1 | Unipolar IS-1 | 5mm | Unipolar LV-1 |
| Receptacle |
6mm | 5mm | Unipolar IS-1 | Unipolar IS-1 |
| Length | 10cm / 40cm | 10cm / 40cm | 10cm / 40cm | 10cm |
C/VS
Implantable lead adaptors consisting of one 6mm receptacle and one IS-1
connector.
M/VS
Implantable lead adaptors consisting of one 5mm receptacle and one IS-1
connector.
VS/M
Implantable lead adaptor consisting of one IS-1 receptacle and one 5mm connector.
LV/IS
Implantable lead adaptor consisting of one LV-1 receptacle and one IS-1
connector
For additional
information and additional adaptors,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model |
DYAD-LV-17 |
DYAD-IS-17 |
| Conductor | Quadrifilar Coil | Quadrifilar Coil |
| Insulation material | Silicone | Silicone |
| Connector | Bipolar IS-1 | Bipolar IS-1 |
| Receptacle |
Bipolar IS-1 Unipolar LV-1 (1.8mm) |
Bipolar IS-1 Unipolar IS-1 |
| Length | 17cm | 17cm |
The DYAD-LV-17
is a bipolar implantable lead adaptor which enables the adaption of one
unipolar LV-1 (1.8mm) connector and one bipolar IS-1 connector to one bipolar
IS-1 pacemaker header cavity.
The DYAD-IS-17 is a bipolar implantable lead adaptor which enables the adaption of one unipolar IS-1 connector and one bipolar IS-1 connector to one bipolar IS-1 pacemaker header cavity.
For additional
information,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
C/VS
Implantable lead adaptors consisting of one 6mm receptacle
and one IS-1 connector.
For additional
information and additional adaptors,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model | C/VS-10 (10cm length) C/VS-40 (40cm length) |
| Conductor | Quadrifilar Coil |
| Insulation | Silicone |
| Connector | Unipolar IS-1 |
| Receptacle | 6mm |
| Length | 10cm / 40cm |
M/VS
Implantable lead adaptors consisting of one 5mm receptacle
and one IS-1 connector.
For additional
information and additional adaptors,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model | M/VS-10 (10cm length) M/VS-40 (40cm length) |
| Conductor | Quadrifilar Coil |
| Insulation | Silicone |
| Connector | Unipolar IS-1 |
| Receptacle | 5mm |
| Length | 10cm / 40cm |
VV
Implantable lead adaptor consisting of one IS-1 receptacle
and one IS-1 connector.
For additional
information and additional adaptors,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model | VV-10 (10cm length) VV-40 (40cm length) |
| Conductor | Quadrifilar Coil |
| Insulation | Silicone |
| Connector | Unipolar IS-1 |
| Receptacle | Unipolar IS-1 |
| Length | 10cm / 40cm |
LV/IS
Implantable lead adaptor consisting of one LV-1 receptacle
and one IS-1 connector
For additional
information and additional adaptors,
please contact Oscor at 1-800-726-7267
For more information
please contact us or call 1-800-726-7267.
CAUTION: FEDERAL LAW (USA) RESTRICTS THIS DEVICE TO SALE, DISTRIBUTION AND
USE BY OR ON THE ORDER OF A PHYSICIAN.
Consult the Instructions For Use for information on indications, contraindications,
warnings and precautions.
| Model | LV/IS-10 (10cm lenght) LV/IS-40 (40cm lenght) |
| Conductor | Quadrifilar Coil |
| Insulation | Silicone |
| Connector | Unipolar LV-1 |
| Receptacle | Unipolar IS-1 |
| Length | 10cm / 40 |